ORIGINAL RESEARCH ARTICLE

The correlation between the depth extent of Tuohy epidural needle with body mass index (BMI) to achieve loss of resistance in patients undergoing epidural anesthesia

I Gusti Agung Gede Utara Hartawan , Tjokorda Gde Agung Senapathi, I Gusti Ngurah Mahaalit Aribawa, Pontisomaya Parami, Adinda Putra Pradhana, Johanis Bosco Troy Syamsuddin

I Gusti Agung Gede Utara Hartawan
Department of Anesthesiology, Pain Management, and Intensive Care, Medical Faculty of Udayana University-Sanglah General Hospital, Denpasar-Bali, Indonesia. Email: utara_hartawan@unud.ac.id

Tjokorda Gde Agung Senapathi
Department of Anesthesiology, Pain Management, and Intensive Care, Medical Faculty of Udayana University-Sanglah General Hospital, Denpasar-Bali, Indonesia

I Gusti Ngurah Mahaalit Aribawa
Department of Anesthesiology, Pain Management, and Intensive Care, Medical Faculty of Udayana University-Sanglah General Hospital, Denpasar-Bali, Indonesia

Pontisomaya Parami
Department of Anesthesiology, Pain Management, and Intensive Care, Medical Faculty of Udayana University-Sanglah General Hospital, Denpasar-Bali, Indonesia

Adinda Putra Pradhana
Department of Anesthesiology, Pain Management, and Intensive Care, Medical Faculty of Udayana University-Sanglah General Hospital, Denpasar-Bali, Indonesia

Johanis Bosco Troy Syamsuddin
Department of Anesthesiology, Pain Management, and Intensive Care, Medical Faculty of Udayana University-Sanglah General Hospital, Denpasar-Bali, Indonesia
Online First: April 28, 2019 | Cite this Article
Hartawan, I., Senapathi, T., Aribawa, I., Parami, P., Pradhana, A., Syamsuddin, J. 2019. The correlation between the depth extent of Tuohy epidural needle with body mass index (BMI) to achieve loss of resistance in patients undergoing epidural anesthesia. Bali Journal of Anesthesiology 3(1): 37-40. DOI:10.15562/bjoa.v3i1.119


ABSTRACT

Background: Anesthesia management in obesity is quite challenging. Epidural anesthesia become one of the choices. The attention should be addressed in order to prevent the misidentification of epidural space. The estimation of the depth extent of epidural space becomes crucial, especially in obese patients due to an accumulation of subcutaneous and epidural adipose tissue, which consequently complicate the epidural catheter insertion. This study aimed to analyze the correlation of the depth extent of Tuohy epidural needle to achieve loss of resistance between normal-weighted and obese patients.

Method: This study was conducted with 56 adult patients aged 17 to 65 years who underwent elective surgery by epidural anesthesia inserted at level L2-L3 or L3-L4 interspace. Subjects are divided into normal and obese groups. Shapiro-Wilk and chi-square tests were used in the normality test. For normally distributed data, an independent t-test was used to test the hypothesis, otherwise, we used Mann-Whitney test  

Results: The results showed that the loss of resistance in epidural needle insertion procedures was 60 mm in a patient with BMI more than 30 kg/m2 and 50 mm in those with BMI <30 kg/m2 (p<0.001).

Conclusion: The loss of resistance depth in epidural Tuohy needle insertion is significantly determined by BMI.

 

References

REFERENCES

Nuttall FQ. Body Mass Index: Obesity, BMI, and Health: A Critical Review. Nutrition Today. 2015; 50(3): 117-128. DOI: 10.1097/NT. 0000000000000092

Heryudarini H, Widodo Y, Mulyati S. Penggunaan Berbagai Cut-Off Indeks Massa Tubuh Sebagai Indikator Obesitas Terkait Penyakit Degeneratif di Indonesia. Journal of the Indonesian Nutrition Association. 2005; 28(2): 1-12. Available at: https://ejournal.persagi.org/index.php/Gizi_Indon/article/view/20

Stefan N, Kantartzis K, Machaan J, et al. Identification and characterization of metabolically benign Obesity in humans. Archives of Internal Medicine. 2008; 168(15): 1609-1616. DOI: 10.1001/archinte.168. 15.1609

Butterworth JF, Mackey DC, Wasnick JD. Epidural Anesthesia. In Morgan & Mikhail’s Clinical Anaesthesiology. Fifth Edition. New York, McGraw-Hill, 2013, pp 958-964.

Paech MJ, Godkin R, Webster S. Complications of obstetric epidural analgesia and anesthesia: a prospective analysis of 10,995 cases. Int J Obstet Anesth. 1998; 7(1): 5-11. Available at: https://www.ncbi.nlm.nih.gov/pubmed/15321239

Ravi KK, Tej KK, Sandeep Khurana, et al. Distance from Skin to Epidural Space: Correlation with Body Mass Index. Journal of Anaesthesiology, Clinical Pharmacology. 2011; 27(1): 39-42. Available at: https://www.ncbi.nlm.nih.gov/pubmed/21804704

Ogunnaike BO, Whitten CW. Anesthesia and Obesity. In: Clinical Anesthesia. Sixth Edition. Barash PG, Cullen BF, Stoelting RK, Cahalan MK, Stock MC, Ortega R (Eds). Philadelphia, Lippincott Williams & Wilkins, 2013, pp 1231-1235

Butterworth JF, Mackey DC, Wasnick JD. Anesthesia for Patients with Endocrine Disease. In Morgan & Mikhail’s Clinical Anaesthesiology. Fifth Edition. New York, McGraw-Hill, 2013, pp 741-743.

Brull Richard, Macfarlane Alan J.R., Chan Vincent W.S. Spinal, Epidural and Caudal Anesthesia In Miller’s Anesthesia. Eight Edition. Miller RD, Eriksson LI, Fleisher LA, et al (Eds). California, Churchill Livingstone Elsevier, 2015, pp 1703-1709

Sutton DN, Linter SP. The depth of extradural space and dural puncture. Anesthesia. 1991; 46(2): 97-8. Available at: https://www.ncbi.nlm.nih.gov/pubmed/1872459

Shiroyama K, Izumi h, Kubo T, et al. Distance from the skin to the epidural space at the first lumbar interspace in a Japanese obstetric population. Hiroshima Journal of Medical Science. 2003; 52(2): 27-9. Available at: https://www.ncbi.nlm.nih.gov/pubmed/12971627

Hirabayashi Y, Matsuda I, Inoue S, et al. The distance from the skin to the epidural space. J Anesth. 1988; 2(2): 198-201. DOI: 10.1007/s0054080020198

Singh S, Wirth K, Phelps A, et al. Epidural catheter placement in morbidly obese parturients with the use of an epidural depth equation prior to ultrasound visualization. The Scientific World Journal. 2013; 25: 695209. DOI: 10.1155/2013/695209.

Adegboye MB, Bolaji BO, Ibraheem GH. The Correlation Between Body Mass Index On The Length From Skin To Lumbar Epidural Space In Nigerian Adults. J West Afr Coll Surg. 2017; 7(1): 113-127. Available at: https://www.ncbi.nlm.nih.gov/pubmed/29951458

Sharma V, Swinson AK, Hughes C, et al. Effect of ethnicity and body mass index on the distance from skin to lumbar epidural space in parturients. Anesthesia. 2011; 66: 907-912. DOI: 10.1111/j.1365-2044.2011.06812.x

Greene NH, Cobb BG, Linnau KF, et al. Measurements of Epidural Space Depth Using Preexisting CT Scans Correlate with Loss of Resistance Depth during Thoracic Epidural Catheter Placement. Anesthesiology Research and Practice. 2015; 2015: 545902. DOI: 10.1155/ 2015/545902.


No Supplementary Material available for this article.